245. Savol: Bizning fabrikamiz alkogol oqava suvlarni davolashadi. Asosiy shartlar quyidagicha: COD<40000 mg/L pH 5-6SS 20000 mg/L TN 500 mg/L SO42- 35 mg/L Temperature 65-75℃. The proposed process is to set up a solid-liquid separator at the front end of the treatment system and connect it to a USAB+ three-tank oxidation ditch at the back. Is this process suitable? If the UASB process is used, should high temperature or medium temperature be used? What else should be paid attention to in the design? A: (1) Medium temperature is better for anaerobic reaction. If the temperature is too high, it should be cooled down. (2) Since anaerobic reaction is sensitive to water quality, water volume and shock load, a large-capacity regulating tank should be built. This is the basic guarantee for the stable operation of anaerobic reaction. (3) Pretreatment process, coarse and fine screens or grit chambers, nutrient salt and pH control systems should be set up according to the characteristics of water quality. (4) It is better to use EGSB or IC for the anaerobic part, and it is recommended to use Carrousel oxidation ditch for the aerobic part.
246. Savol: Bizning zavodimizning davolash ko'lami 30,000 m3 / d ni tashkil qiladi. Biz gidrolize + biologik aloqa oksidlanish jarayonini davolashni qabul qildik. Ikki yillik operatsiyadan so'ng ikkinchi darajali cho'kindi idishi har doim suzuvchi loy (taxminan 0,9). Biz turli xil sozlash usullarini sinab ko'rdik, ammo hech qanday foyda keltirmadik. Dastlab biz ikkinchi darajali cho'kindi tankining dizayni yuklanishi juda yuqori ekanligiga ishonamiz. Iltimos, tasdiqlang. Javob: Garchi biz loyqalashning ishlashi yaxshi, ikkinchi darajali cho'kindi kaptarining sirt yukidan, sizning fikringiz to'g'ri. Endi tushunmovchilik mavjudligi sababli aloqa koofsalmsi juda ko'p biofilmga ega emas va cho'kindi idishning yuzasi balandroq bo'lishi mumkin. Kontaktli koksidli idishidan keyin ko'plab cho'kindi tanklarining yuzasi faol loy cho'kindi cho'kindi tankiga o'xshash. Bu noto'g'ri. Membrananing yuzasi cho'kindi tankining sirt yuki loy cho'kindi idishidan kichikroq bo'lishi kerak, chunki Shag'al biofilmning ishlashi odatda kambag'al.
247. Savol: Bugun ertalab, kanalizatsiya stantsiyamiz aeratsiya xizmatida to'rtta erigan kislorod hisoblagichini 4,0 mg / l ga yaqindan tushirib yuborganini aniqladik va biokimyoviy tank evaziga aeratsiya qilingan. Ammo qiymati hali ham ko'tarilmadi. To'rt evropalik kislorod o'lchagichning displey qiymatlari bir xil bo'lganligi sababli, erigan kislorod hisoblagichining etishmovchiligi uni rad etish mumkin. Javob: Tug'ganik kodning juda ko'pmi yoki yo'qligini tasdiqlash kerak.
248. Savol: Qo'rg'oshin ioni odatda elektroplatsion oqava suvlarda davolanadi? Oqava suv oqimi sulfidga qo'yadi, ammo sulfat uchun talablar bormi? Javob: Elektrolyater, masalan, faollashtirilgan uglerod va boshqalar kabi adbitsitik oqava suvlar, adsorbsiya kabi etakchi ionlarni olib tashlashning ko'plab usullari mavjud.
249. Savol: Kasalxonalarni davolash uchun kanalizatsiyalash moslamasi kuniga 300 kubometr suv hajmiga, 1,5 kun davomida anaerobik davolash va 1,5 kun davomida oksidlanish bilan aloqa qilish. Ampret asosan ambulatoriya va statsionar oqava suvdir. Tarozi eng yaxshi sariq va anaerob ta'siri juda kambag'al. Effuktali kodi 300mg / l va ammiak azoti 55mg / l ni tashkil qiladi. Kontakt oksidlanishining oqova kodi 180mg / l va ammiak azot 35mg / l ni tashkil qiladi. Men deyarli yarim yil davomida rivojlandim, ammo ta'siri shunda. Men loyni ko'p marta qo'shdim, ammo foydasiz. Men yaqinda un qo'shishni boshladim va u biroz yaxshilandi. Kerakli cheklovlar tufayli men har kuni 10 kg un qo'shaman. Qanday qilib biofilmni samarali ravishda o'stira olaman? Javob: Siz asosiy nazorat shartlari bajarilganligini tasdiqlashingiz kerak, masalan, teorri, harorat nisbati (fosforning fosforli ishqorsizligi) va aloqa oksidi idishi Chunki kirish juda oddiy, men faqat shunga o'xshash javob bera olaman.
250. Savol: Bizning jihozimizning oqavatimizni tozalash moslamasi A / O usulini qabul qiladi. Odatda, basseynda ammiak azoti 38mg / l va o basseyn 9mg / l ni tashkil qiladi. Endi hovuzda ammiak azoti 60mg / l va o basseyn 45mg / l ni tashkil qiladi. Ammiak azotini kamaytirmasa, sulfidning o'sishi bilan bog'liqmi? Bu kunni yig'ish kuni bo'ldi, ammo vaziyat yaxshilanmadi. Ishlash sharoitlari o'zgarmadi. To'satdan u shunday bo'ldi. O'rtada faqat ikkita narsa yuz berdi: 1. Sulfid kuchayadi; 2. Cod ortdi va neft va suv bor edi. Shundan so'ng, pastga tushdi va loy jigar rangdan qora ranggacha o'girildi. Endi nima qilishim kerak? Javob: Men sulfid kontsentratsiyasi qanchalik balandligini bilmayman, lekin siz taqdim etgan vaziyatdan, loydan zaharlanish ehtimoli yuqori emas. Asosiy sababi shundaki, kislorodli ta'minotni etishmay, aqlli anaerobizmni keltirib chiqaradi. Oldingi vaziyatlarga kislorod etishmasligi. Kislevatsiya summasi iloji boricha ko'payishi va suvni iste'mol qilish kamayishi kerak. Agar kislorod miqdori ko'paytirilmasa, loydan tushirish summasi loy konsentratsiyasini kamaytirish uchun mos ravishda ortadi. Ushbu yondashuv uch fazali muvozanat printsipiga zid bo'lganga o'xshaydi, chunki loy ko'tarish balandroq, ammo bunday emas. Chunki loydan bo'sh oqim summasini ulg'ayishi mumkin, shuning uchun etarli miqdordagi moddalarni libosda qoldirishi mumkin, ular kislorod etishmovchiligini yumshatish foydali bo'ladi. Ushbu davolash yaxshiroq bo'ladi.
251. Savol: Bizning oqava suvlarimiz 500 dan 600 mg / l gacha. Biz alum + pam koagulyatsiyasining flotatsiyasi usulidan foydalandik, ammo davolash ta'siri yaxshi emas edi. Men eksperimental davolanish uchun vodorod perokid + qora sulfatni ishlatganman (COD 150 mg / l atrofida). Endi savol tug'iladi: temir gidroksidi cho'kma bosimli flotatsiya bilan olib tashlanadimi? Javob: Temir gidroksidining o'ziga xos tortish kuchi nisbatan katta, shuning uchun u flotatsiya uchun mos emas.
252. Savol: Oksidlanish Biofilm shakllanishi haqida: 1. O idishni boshida shilimshiq loyning 5 foizi qo'shildi. Garchi faol nukular bo'lmasa ham, o'lik loy, tizimdan qanday yo'qoladi? Yagona organizmlarga oqilona va suv yoki aerobik hazm qilish bilan oqadimi? Yoki uzluksiz suv oqimi orasidan keyin o'lik bo'lmagan loy bilan birlashtirilgan va cho'kindi idishdan kichik flokchalar sifatida oqardimi? 2 Bu vaqtda, suvda to'xtatilgan loyning tegishli konsentratsiyasi qanday? 3 Pliterga loyqa yopishtirish va plomba ustiga loyning tez ko'payishi va o'sishi qanday usullar bilan ta'minlanadi? Javob: 1. Aerob sharoitida faoliyatini tiklash uchun ba'zi o'lik nosozliklar mavjud bo'lgan ba'zi navbatda ishlaydigan aerobik bakteriyalar mavjud. Ba'zi o'zgaruvchan qattiq moddalar bakteriyalar ham buzilishi mumkin. Suvni iste'mol qilish atmosferaga ta'sir qilish kerak bo'lgan oz miqdordagi loydan so'ng, suvni iste'mol qilishning ko'payishi kerak bo'lgan oz miqdordagi loydan so'ng, ozgina loy suv bilan suzadi, suvni iste'mol qilishning ko'payishi kerak (ozuqaviy moddalar o'z vaqtida to'ldirilishi kerak). Bu vaqtda, {{14} suvda loyqa bo'lmagan neftda neftsizlangan loydan foydalanish mumkin emas. Suvsizlanishdan oldin konsentrlangan loyni emlash uchun ishlatilishi kerak, yoki urug 'loyqa plomba moddasi biokimyoviy basseynga qo'shiladi. Albatta, muayyan etishtirish jarayonida texnik talablar mavjud.
253. Savol: Biz charm oqava suvlarni tozalash zavodini, jarayonni olib tashlaymiz: ekran - ikki bosqichli flevtulyatsiya idishi - Cho'kindi Tank - Cho'kindi Tank - Cho'kindi cho'kindi Imkoniyat hajmi 700m3 / d, infrull kodi 3000 mg / l dan ko'proq, va effolatlar kodi 90 mg / l dan past bo'lishi kerak. Faollashtirilgan loy idishi SRT 9,3 soatni tashkil qiladi, SRT 4 soat, va ikkinchi darajali cho'kindi kursi 2 soatni tashkil qiladi. Birinchi loy qo'shilganidan so'ng, hech qanday avervat yo'q edi va doimiy ravishda reflur madaniyati amalga oshirildi. Ko'pik va hid juda og'ir edi va biokimyoviy basseynning olib tashlanishi yaxshilanmadi. Keyinchalik, ikkinchi loy qo'shildi va effekt bir necha kunlik aeratsiyadan keyin aniq va asta-sekin tozalangan suv miqdorini oshirdi. Fizikaviy va kimyoviy jarayonning oqim kodi taxminan 700-1000 mg / l edi va oraliq cho'kindi tankning kodi 200 mg / l edi. Oksidlanishdan so'ng, kod hali ham 100 mg / l dan oshdi, bu hali ham dizayn talabidan yuqori (90mg / l dan past). Operatsiya davomida faollashtirilgan loy idishlari ham, aloqa oksidi idishi ham loyqa qaytishdi. Keyinchalik faollashtirilgan loy idishi qaytib kelish uchun sozlangan va aloqa oksidiatsiyasi qaytarilmadi. Biroq, aloqa oksidiatsiyasida ko'pik o'sdi. Ikkilamchi cho'kindi bir necha daqiqa davomida bir necha daqiqa drenajlangan, ammo efirlar hali ham juda ko'p ss va olib tashlash ta'siri yaxshilanmagan. Endi menda bir nechta savol bor: 1 Standart nima (SVI va MLSS o'lchash uchun shart emas)? 2. Jismoniy guvohlik berishning umumiy fosfor - bu atigi bir necha o'ninchi va C / P juda past. Faollashtirilgan loy idorasidagi loy endi kengaymoqda. Bunga bog'liqmi, deb o'ylayman? 3. Agar siz fosforli o'g'it miqdorini hisoblamoqchi bo'lsangiz, uni qanday hisoblash kerak? Siz misol keltira olasizmi (fosforli o'g'itning samarali tarkibiy qismi: P2O {5=12? 4 Hovuzda kam uchragan loydan kam uchraydigan iffding borligini aralashtirish osonmi? Qaytish yoki uning yuki bilan aniqlanmaganmi? Mlslar yuqori bo'lganda, MLSlar past va suvni davolash uchun faqat membranaga suyanganida, yukni almashtirish uchun ba'zi shartli loyni qo'shish mumkinmi? 5 6 Javob: Javoblar quyidagicha: 1. Agar mls o'lchanmasa, SV o'lchanishi kerak, bu loy va loyning ishlashi miqdorini aniqlay oladi. Endi loy faqat taniqli va etishtiriladigan loydan iborat bo'lib, fosforning etarli emasligi sababli fosforning etarli emasligi sababli fosfor osonlikcha yomonlashib, loyqa o'sishga ta'sir qilishi mumkin. Fosfor biokimyoviy basseynning bod5 ning 1% miqdorida boshqarilishi kerak. Agar bu etarli bo'lmasa, uni qo'shilishi kerak, shuningdek, Bod5 o'lchanmagan bo'lsa, n {{53} talablarga javob berishini tasdiqlash kerak, qo'shimcha ravishda fosfor miqdori sinov va xato bilan bog'liq bo'lishi mumkin. Fosfor kontsentratsiyasi elementar fosfor deb ifodalanadi. Agar soatiga x kg toza fosfor qo'shiladi, {× p2o5 / p} summasi {p2o5 / p} summasi, kontakt oksidon ko'ylagining yuzasida bu kontakt oksidi ko'ylagi bilan bog'liq emas. Endi ko'pikni kamaytirish uchun og'ir loydan foydalanish, asosiy echim emas, balki yuzaki davolanishdir. Umuman olganda, biofilm to'liq shakllanganidan keyin ko'pik pasayadi. Agar u hali ham yo'qolmasa, u ({68}} ko'pikni yo'q qilish uchun püskürtülmünni kengaytirish uchun qabul qilib bo'lmaydi. Bu hali ham ozuqaviy nisbatlar muammosi bo'lishi mumkin. Inmiochemik hovuz suvi 6 ~ 9 da nazorat qilinishi mumkin. Bundan tashqari, shuni ta'kidlash kerakki, kontakt oksidlanish usulining normal ishlashi paytida loyni anglatadi. Buni madaniyat davrida tegishli tarzda o'tkazish mumkin, ammo ovqatlanish etarli bo'lmaganda uni hal qilish mumkin emas. Agar ozuqaviy nisbatlar qondirilmasa, loyni qo'shish befoyda.
254. Savol: Ikkilamchi cho'kindi qatlamidan so'ng, oksidlashning ikkinchi cho'kindi tarkibida nefdlash kooperatsion oksidlash tankiga qaytarilishi kerakmi yoki loyni etishtirishning keyingi bosqichiga qaytarilishi kerakmi? Skrit mikroskopik tekshiruvida bir necha sonli qo'ng'iroq qurtlari va tarqalgan qurtlar topilsa va uni qaytarib berishning hojati yo'q deb hisoblash mumkin (oddiy ma'noda uni qanday boshqarish kerak bo'lsa, u faqat suv to'liq yuklanganda to'xtatilishi kerakmi? Javob: Agar plombadagi oz miqdorda biofilm bo'lsa, ikkinchi darajali cho'kindi sumka, aks holda loydagi mikroorganizmlar bilan mikroorganizmlar bilan ovqatlanishadi. Agar biofilm hali shakllanmagan bo'lsa, suvni tizimda aylantirish va emlash roliga olib kelishi uchun suv olishni ko'paytirishi mumkin. Iljonlik qilishning etukligi deyarli biologik fazada hukm qilinishi mumkin. Ildul hosil bo'lganida ba'zi suzish protozosi paydo bo'ladi. Agar qo'ng'iroq qurtlari va tarqalgan qurtlar ko'p sonli bo'lsa va faol bo'lsa, u odatda aloqa oksidlanishini biofilmning muvaffaqiyatli bo'lishi mumkin deb hisoblash mumkin. Biroq, istisnolar mavjud. Ba'zi oqova suvlarni davolash moslamalari odatda ishlaydi, ammo ularda kam sonli protozoa mavjud, shuning uchun SV va boshqa omillarni tahlil qilish uchun birlashtirish kerak. Biofilmning dastlabki shakllanishidan so'ng, agar maxsus vaziyat bo'lmasa, ikkinchi darajali cho'kindidagi loyni qaytarish kerak emas.
255. Savol: Oddiy ochiq anaerobik kulgili kulgili og'riq yo'qoldi, qaytarish hajmini qanday boshqarish mumkin? Qanday qilib silkitgichni o'rnatish kerak? Agar suv osti sirer ishlatilsa, qanday nazorat zonasi talab qilinadi? Javob: Haqoratli anaerobik reaktorning loy va suv aralashmasi suvning yuqoriga va oqim oqimini almashtirish orqali erishiladi, shuning uchun sirtni o'rnatishning hojati yo'q. Qaytarish hajmi bilan deyarli bog'lanmaydigan anaerob loyni yo'qotish uchun ko'p sabablar mavjud.
256. Savol: Suv oqimi paytida suv oqimi paytida oksidlash sharqida biofilm shakllanishiga yordam bermaydimi? Suv oqimidan oldin yoki undan keyin har bir biokimyoviy tankga qo'shilgan ozuqa qo'shilishi? Suv oqimi paytida qo'shimcha ozuqa yo'qotishiga olib keladimi? Javob: Biofilm etishtirish jarayonida ozuqa yoki suv oqimini aeratsiya qilish yoki suv oqimi aeration bo'ladimi, bu yo'qotishni minimallashtirishdir. Men suv oqimi paytida averatsiya biofilm shakllanishiga yordam bermaydi deb o'ylamayman. Suv oqimi etishtirishning kaliti suv oqimi va aeratsiya hajmini boshqarishdir.
257. Savol: Bizning kompaniyamiz ko'p miqdordagi benzen halqa moddalarini o'z ichiga olgan farmatsevtika oqavatiga ega. Suv hajmi 600t / d ni tashkil qiladi va o'rtacha grifentli kod 27000 mg / l. Jarayon: Stanretatsiya + anaerobik + faollashtirilgan loy basseyn + ikkita seriyali oksidlash havzalari. Hozirgi oqovat 300 mg / l ga teng (talab birinchi darajali kompensatsiya standarti, Cod100MG / L yoki undan kam). Kontakt oksidlanishining kodi 200 mg / l ga tushirildi va boshqa hech qachon kamaytirilmaydi. Agar u havolangan bo'lsa, u yana ko'tariladi. Endi biz sof kislorod aereratsiyasidan foydalanmoqchimiz, avval u ishlashini bilish uchun tajriba sinovini o'tkazishni va shuningdek harakat qilish uchun faollashtirilgan uglerod qo'shishni rejalashtirmoqdamiz. Boshqa usullar bormi? Javob: Operatsion boshqaruvni boshqarish bilan bog'liq omillar bundan mustasno, agar kodi faqat 200 mg / l ga tushirilishi mumkin bo'lsa, defevaderning b / c nisbati juda kam ekanligini anglatadi; Agar u gazlangan bo'lsa, u yana ko'tariladi, shuni ko'rsatadiki, aeratsiya vaqti juda uzoq ekanligini va biofilm qariyb va qisman parchalangan. Sof kislorod avereratsiyasidan foydalanish sababi, tekshirish uchun idish etarli kislorodni etkazib bera olmaydi? Agar oqava suv kambag'al biologik parchalanishiga qaramay, toza kislorod aeratsiya foydasizdir. Yozish faollashtirilgan uglerod foydali, ammo bu tejamkor emas. Men ushbu jarayon kombinati muammoli ekanligini his qilaman va anaerob jarayoni oldin qanday oldindan tayyorgarlik jarayoni nima ekanligini bilmayman, shuning uchun men yana izoh berolmayman.
258. Savol: PAK va Pamni flotatsiya idishga qo'shgandan so'ng, reaktsiya kamerasida aniq tabaqalanish mavjud. Jutadan 30 sm, pastki qatlamning barchasi xiralashgan cho'kindi. Oqim flotal kameraga oqib chiqgandan keyin turbid bo'ladi. Nima gaplar? Buni qanday hal qilish kerak? Javob: Men Kaf yoki DAFdan foydalanayotganingizni bilmayman. Siz aytganingizga ko'ra, flokular agentni qo'shgandan keyin ishlab chiqariladi, ammo flokulyatsiya ta'siri unchalik yaxshi emas. Buning uchun agent qo'shimcha jarayonida muammo borligini tasdiqlashni talab qiladi. PAC va Pam bir vaqtning o'zida qo'shilmaydi. Alohida qo'shimcha qo'shimchalar bo'lishi kerak va flokulyatsiya jarayoni to'g'ri aralashmasi va aralashtirish kerak. Agar regentsiyalarni qo'shish omili chiqarib tashlansa, bu flotatsiya inshootlari va uskunalarining muammolari, masalan: etarli darajada gazli suyuq interfeys; Agar havo tank bo'lsa, havo idishining bosimi normal ekanligini tasdiqlang;
259. Savol: Suv suv oqimi paytida oksidlanish oksidlash oksidi oksidlash oqimlari biofilm shakllanishiga zararli bo'lganmi? Suv oqimidan oldin yoki undan keyin har bir biokimyoviy tankga qo'shilgan ozuqa qo'shilishi? Suv oqimi paytida ozuqa moddasi ozuqani yo'qotishiga olib keladimi? Javob: Biofilm etishtirish jarayonida ovqatlanish yoki suv oqimi aeration bo'lishidan qat'i nazar, u aeratsiya yoki suv oqishini aeratsiya qilishning oldini olish mumkin emas va bu yo'qotishni minimallashtirishdir. Men suv oqimi paytida averatsiya biofilm shakllanishiga zararli deb o'ylamayman. Suv oqimi etishtirishning kaliti suv oqimi va aeratsiya hajmini boshqarishdir.